DocumentCode
3777906
Title
Hydropower unit primary frequency control model analysis
Author
Meng-Di Liu; Zhen Jia; Hong-Tao Li; Yuan-Chu Cheng
Author_Institution
Wuhan University, 430072, China
fYear
2015
Firstpage
360
Lastpage
364
Abstract
Primary frequency of hydropower unit plays an important role in the stability of the grid frequency. The operation mode of hydropower governor has remarkable effect on the frequency modulation. In this paper, frequency power integrated control mode and frequency power select control mode were introduced, as well as the analysis of their static and dynamic characteristics, and frequency power select control mode was recommended. The select control mode can effectively improve the power control and primary frequency response speed.
Keywords
"Frequency control","Frequency modulation","Hydroelectric power generation","Power control","Torque","Power system stability"