Abstract
This paper investigates electrical breakdown of interconductor insulation, which presents an obstacle to the increase of the rated voltage of electrical machines as a means to improve efficiency of electrical energy exploitation. We have investigated a large number of samples searching for weak points in interconductor insulation along the coil of a high voltage asynchronous machine. The experiments were performed on lacquer-glass-glass-lacquer conductor insulation. Location of weak points and breakdown voltage levels have been determined.
Keywords
"Stator windings","Breakdown voltage","Dielectrics and electrical insulation","Voltage control","Machine windings","Partial discharges","Conductors","Protection","Synchronous generators","Copper"