• DocumentCode
    3807489
  • Title

    Robust Gradient-Based 3-D/2-D Registration of CT and MR to X-Ray Images

  • Author

    Primo? Markelj;Dejan Tomazevic;Franjo Pernus;Bo?tjan Likar

  • Author_Institution
    Fac. of Electr. Eng., Univ. of Ljubljana, Ljubljana
  • Volume
    27
  • Issue
    12
  • fYear
    2008
  • Firstpage
    1704
  • Lastpage
    1714
  • Abstract
    One of the most important technical challenges in image-guided intervention is to obtain a precise transformation between the intrainterventional patient´s anatomy and corresponding preinterventional 3-D image on which the intervention was planned. This goal can be achieved by acquiring intrainterventional 2-D images and matching them to the preinterventional 3-D image via 3-D/2-D image registration. A novel 3-D/2-D registration method is proposed in this paper. The method is based on robustly matching 3-D preinterventional image gradients and coarsely reconstructed 3-D gradients from the intrainterventional 2-D images. To improve the robustness of finding the correspondences between the two sets of gradients, hypothetical correspondences are searched for along normals to anatomical structures in 3-D images, while the final correspondences are established in an iterative process, combining the robust random sample consensus algorithm (RANSAC) and a special gradient matching criterion function. The proposed method was evaluated using the publicly available standardized evaluation methodology for 3-D/2-D registration, consisting of 3-D rotational X-ray, computed tomography, magnetic resonance (MR), and 2-D X-ray images of two spine segments, and standardized evaluation criteria. In this way, the proposed method could be objectively compared to the intensity, gradient, and reconstruction-based registration methods. The obtained results indicate that the proposed method performs favorably both in terms of registration accuracy and robustness. The method is especially superior when just a few X-ray images and when MR preinterventional images are used for registration, which are important advantages for many clinical applications.
  • Keywords
    "Robustness","Computed tomography","X-ray imaging","Image reconstruction","Anatomy","Image registration","Anatomical structure","Iterative algorithms","Magnetic resonance","Image segmentation"
  • Journal_Title
    IEEE Transactions on Medical Imaging
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2008.923984
  • Filename
    4494445