  • Title

    PQ Monitoring System for Real-Time Detection and Classification of Disturbances in a Single-Phase Power System

  • Author

    Tom?? Radil;Pedro M. Ramos;Fernando M. Janeiro;A. Cruz Serra

  • Author_Institution
    Inst. de Telecomun., Lisbon
  • Volume
    57
  • Issue
    8
  • fYear
    2008
  • Firstpage
    1725
  • Lastpage
    1733
  • Abstract
    This paper presents a system for detection and classification of power quality (PQ) voltage disturbances. The proposed system applies the following methods to detect and classify PQ disturbances: digital filtering and mathematical morphology are used to detect and classify transients and waveform distortions, whereas for short- and long-duration disturbances (such as sags, swells, and interruptions), the analysis of the root-mean-square (RMS) value of the voltage is employed. The proposed combined approach identifies the type of disturbance and its parameters such as time localization, duration, and magnitude. The proposed system is suitable for real-time monitoring of the power system and implementation on a digital signal processor (DSP).
  • Keywords
    "Monitoring","Real time systems","Power systems","Power system transients","Voltage","Power quality","Digital filters","Filtering","Morphology","Transient analysis"
  • Journal_Title
    IEEE Transactions on Instrumentation and Measurement
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2008.925345
  • Filename
    4538260