DocumentCode
3809495
Title
Mutual Inductance of a Precise Rogowski Coil in Dependence of the Position of Primary Conductor
Author
Luka Ferkovic;Damir Ilic;Roman Malaric
Author_Institution
Dept. of Fundamentals of Electr. Eng. & Meas., Univ. of Zagreb, Zagreb
Volume
58
Issue
1
fYear
2009
Firstpage
122
Lastpage
128
Abstract
The Rogowski coil is a well-known current-to-voltage transducer. To use it for the high-accuracy measurement of AC current (at power supply frequency), all influencing quantities and their contribution should be recognized and analyzed. Thus, the partial influence due to the deviation from the central position of the primary conductor for a real sensor, with the nonhomogeneous density of secondary turns, is given in this paper. The measured deviation of mutual inductance in this case showed very good agreement with the theoretical prediction, which is promising for the expected application of such a sensor.
Keywords
"Inductance","Coils","Conductors","Current measurement","Geometry","Transducers","Power measurement","Frequency measurement","Power supplies","Magnetic sensors"
Journal_Title
IEEE Transactions on Instrumentation and Measurement
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2008.928412
Filename
4635031
Link To Document