• DocumentCode
    3849267
  • Title

    Passivity-based control of a wound-rotor synchronous motor

  • Author

    A. Doria-Cerezo;C. Batlle;G. Espinosa-Perez

  • Author_Institution
    Department of Electrical Engineering and Institute of Industrial and Control Engineering, Universitat Politecnica de Catalunya, EPSEVG, 08800 Vilanova i la Geltru, Spain
  • Volume
    4
  • Issue
    10
  • fYear
    2010
  • fDate
    10/1/2010 12:00:00 AM
  • Firstpage
    2049
  • Lastpage
    2057
  • Abstract
    This study presents a new non-linear passivity-based controller for a wound-rotor synchronous machine, acting as a motor drive. The control objectives are stated in the dq-frame, and the port-controlled Hamiltonian model is also obtained. A power flow analysis allows to state the control goals in terms of ohmic losses reduction, and motivates the use of the field current for the reactive power compensation. From the Hamiltonian structure, the simultaneous interconnection and damping assignment technique is used to compute the control action, which results in a controller with a simpler architecture than the standard one for this class of machines, able to cope with both positive and negative external mechanical loads and having thus bidirectional power capabilities. The robustness of the control action is also taken into account in the design procedure. Finally, the computed controller is validated via numerical simulations.
  • Journal_Title
    IET Control Theory & Applications
  • Publisher
    iet
  • ISSN
    1751-8644
  • Type

    jour

  • DOI
    10.1049/iet-cta.2009.0641
  • Filename
    5611725