• DocumentCode
    3849342
  • Title

    Experimental Verification of Deep Field Weakening Operation of a 50-kW IPM Machine by Using Single Current Regulator

  • Author

    Yuan Zhang;Longya Xu;Mustafa K. G?ven;Song Chi;Mahesh Illindala

  • Author_Institution
    The Ohio State University, Columbus, OH, USA
  • Volume
    47
  • Issue
    1
  • fYear
    2011
  • Firstpage
    128
  • Lastpage
    133
  • Abstract
    This paper analyzes critical control issues associated with the deep field weakening operation of interior permanent magnet (IPM) synchronous machines. The singlecurrent-regulator control algorithm is reviewed, which controls the d-axis current actively and gives a fixed q-axis voltage command. To achieve better operational efficiency and performance, improvements are made to choose an optimal q -axis voltage for variable-speed and variable-load conditions. The control algorithm is implemented on a 50-kW IPM machine. Test results, including 7:1 constant power speed ratio operation, are presented to verify the theoretical analysis.
  • Keywords
    "Voltage control","Torque","Regulators","Permanent magnets","Algorithm design and analysis","Windings","Current control"
  • Journal_Title
    IEEE Transactions on Industry Applications
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2010.2091478
  • Filename
    5629360