DocumentCode
3861550
Title
Aging and rejuvenation of a TMAE+methane multiwire photon detector
Author
S. Korpar;P. Krizan;A. Stanovnik;M. Staric;D. Skrk
Author_Institution
Jozef Stefan Inst., Ljubljana Univ., Slovenia
Volume
46
Issue
3
fYear
1999
Firstpage
317
Lastpage
320
Abstract
A UV sensitive multiwire photon detector has been tested as a possible candidate for the HERA-B RICH detector. The main obstacle to using such a TMAE+Methane filled gas detector in a high rate experiment appears to be rapid aging in the form of prohibitive loss of chamber gas gain. A special circuit has been designed for heating the anode wires in-situ with elevated currents, thus evaporating the polymer deposits. Heating almost completely recovers the initial gain, but this rejuvenation is unfortunately of short duration. Nevertheless, the cells exposed to periodic heat treatments have an average gain considerably higher than the non-heated cells.
Keywords
"Aging","Detectors","Anodes","Wires","Mesons","Bridges","CAMAC","Heating","Heat recovery","Testing"
Journal_Title
IEEE Transactions on Nuclear Science
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.775536
Filename
775536