• DocumentCode
    432052
  • Title

    Identification of ultrasound-contrast-agent dilution systems for cardiac quantification

  • Author

    Mischi, M. ; Kalker, A.A.C.M. ; Korsten, H.H.M.

  • Author_Institution
    Tech. Univ. Eindhoven, Netherlands
  • Volume
    1
  • fYear
    2004
  • fDate
    23-27 Aug. 2004
  • Firstpage
    13
  • Abstract
    This study presents a new minimally-invasive indicator dilution technique for cardiac quantification. An ultrasound contrast agent bolus is injected in a peripheral vein and detected by an ultrasound transducer. Several acoustic-intensity time curves are measured in specific regions of interest. After calibration, the resulting curves are processed by a Wiener deconvolution filter to identify the dilution system between different measurement sites, which is characterized by its impulse response function. This is interpolated and interpreted by specific models for the assessment of ejection fraction (EF) and pulmonary blood volume. The EF assessment is tested on a group of 20 patients with left ventricular EF going from 10% to 70%. The results show a 0.93 correlation coefficient with echographic hi-plane measurements. Blood volume measurements are validated in vitro and show a 0.99 correlation coefficient with the real volumes. The method feasibility is also tested in patients with promising results. In conclusion, the echographic identification of biological dilution systems is feasible. It allows a minimally invasive measurement of pulmonary blood volume and EF. The promising results encourage further validation and investigation for new applications.
  • Keywords
    Wiener filters; blood flow measurement; deconvolution; echocardiography; patient monitoring; Wiener deconvolution filter; acoustic-intensity time curves; cardiac quantification; correlation coefficient; echocardiography; left ventricular ejection fraction; minimally-invasive indicator dilution technique; pulmonary blood volume; ultrasound contrast agent bolus; ultrasound transducer; ultrasound-contrast-agent dilution systems; Acoustic measurements; Acoustic signal detection; Acoustic transducers; Blood; Testing; Ultrasonic imaging; Ultrasonic transducers; Ultrasonic variables measurement; Veins; Volume measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2004 IEEE
  • ISSN
    1051-0117
  • Print_ISBN
    0-7803-8412-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2004.1417656
  • Filename
    1417656