DocumentCode
432326
Title
Clamp-on shear transducers simplify torsional and extensional investigations [mass flowrate measurement]
Author
Lynnworth, L.C. ; Cohen, R. ; Nguyen, T.H.
Author_Institution
GE Infrastructure Sensing, Billerica, MA, USA
Volume
3
fYear
2004
fDate
23-27 Aug. 2004
Firstpage
1603
Abstract
This paper treats several practical aspects of using torsional waves in solid sensors to measure fluid density F. As is well known, the product of F and flow velocity V leads to mass flowrate MF. Determining MF was an important motivator of the present work. This present study consisted mainly of combining several incremental waveguide improvements with a new clamp-on shear transducer couple to launch torsional waves, extensional waves, or both, in elastic waveguides containing one or more sensor zones.
Keywords
acoustic waveguides; density measurement; elastic waves; flow measurement; ultrasonic measurement; clamp-on shear transducers; elastic waveguides; extensional waves; fluid density measurement; mass flowrate measurement; solid sensors; torsional waves; Acoustic sensors; Density measurement; Fluid flow measurement; Interference; Liquid waveguides; Shape; Solids; Temperature sensors; Transducers; Waveguide transitions;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 2004 IEEE
ISSN
1051-0117
Print_ISBN
0-7803-8412-1
Type
conf
DOI
10.1109/ULTSYM.2004.1418127
Filename
1418127
Link To Document