Using the Medipix2 detector for photon counting computed tomography
Author
Niederlöhner, Daniel ; Nachtrab, Frank ; Michel, Thilo ; Anton, Gisela
Author_Institution
Physikalisches Inst., Erlangen-Nurnberg Univ., Erlangen, Germany
Volume
4
fYear
2005
fDate
23-29 Oct. 2005
Firstpage
2327
Lastpage
2331
Abstract
The Medipix2 detector is a photon counting hybrid pixel detector. It consists of 256 by 256 pixels (55×55 μm2 each) with a semiconductor sensor layer. Two thresholds enable X-ray imaging with an energy window. Integration of this detector into our setup requires very precise alignment of all devices: Precision of up to 0.05° and 10 μm was realised with special objects. For the verification of the system resolution we constructed phantoms with high contrast at high spatial frequency. The resolution limit of our setup is about 50 μm which is dominated by the relatively large X-ray spot size. Further on we investigated the impact of flatfield correction on ring artifacts and additionally applied a special filtering algorithm for suppression of those. Computed tomography acquisition series with different organic objects have been carried out to prove the system performance for realistic imaging tasks: Using a peanut as well as a newborn mouse produced high quality volume data sets. In addition, we used the quad version of the Medipix2 detector (2×2 ASICS) for CT of larger objects with diameters up to 26 mm. With Monte-Carlo simulations we investigated the interaction of energy weighting with the filtered back projection algorithm if energy resolved data is available: Applying the energy weighting technique before filtering and back projection or afterwards; or with intermixed order for different energy intervals and different kernels. We propose weighting before filtering and recommend smoothing kernels for lower photon energies and high resolution kernels for energy intervals with higher statistics.
Keywords
computerised tomography; filtering theory; image resolution; medical image processing; phantoms; smoothing methods; Medipix2 detector; Monte Carlo simulations; X-ray imaging; energy weighting; filtered back projection algorithm; filtering algorithm; flatfield correction; phantoms; photon counting computed tomography; photon counting hybrid pixel detector; ring artifacts; semiconductor sensor layer; smoothing kernels; system resolution; Computed tomography; Detectors; Energy resolution; Filtering; Kernel; Object detection; Optoelectronic and photonic sensors; Single photon emission computed tomography; Spatial resolution; X-ray imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2005 IEEE
ISSN
1095-7863
Print_ISBN
0-7803-9221-3
Type
conf
DOI
10.1109/NSSMIC.2005.1596800
Filename
1596800
Link To Document