    Count Rate Performance and Dead Time in Singles Transmission Scanning for the microPET Focus 220 Scanner

  • Author

    Lehnert, Wencke ; Meikle, Steven R. ; Newport, Danny F.

  • Author_Institution
    Sch. of Med. Radiat. Sci., Sydney Univ., NSW
  • Volume
    4
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    2484
  • Lastpage
    2487
  • Abstract
    Count rate loss in singles transmission scans due to dead time can decrease the accuracy of attenuation correction if not corrected and adds noise to the data. The aim of this study was to investigate count rate performance and dead time in singles transmission scanning on the microPET Focus 220 animal scanner, and to determine the optimal range of activity for accurate attenuation correction. A point source filled with 99mTc was used due to the similarity of its photon energy (140 keV) to that of 57Co (122 keV) which was previously found to provide accurate attenuation coefficients. Transmission scans were performed with the isotope decaying and using wide (21%) and narrow (4%) energy windows to evaluate different components of dead time. We found that count rate losses occur at the detector level and in the front end electronics for transmission sources with activities higher than 80 MBq, independent of energy window width. Further losses and mispositioning artifacts emerged due to multiplexing at the detector head interface for activities higher than 150 MBq for the wide energy window. Substantial count rate losses during transfer of the list mode data from the microPET to the PC were also observed for this condition. The bias and noise in attenuation correction factors and reconstructed attenuation coefficients suggest that a useful activity range is 10 to 150 MBq for 57Co singles transmission studies.
  • Keywords
    image denoising; image scanners; isotope detection; nuclei with mass number 90 to 149; photon counting; positron emission tomography; 140 keV; 57Co; 99mTc; artifacts; attenuation coefficients; attenuation correction; count rate performance; data noise; dead time; detector head interface; front end electronics; isotope decay; microPET Focus 220 scanner; multiplexing; photon energy; singles transmission scanning; Animals; Attenuation; Detectors; Head; Image reconstruction; Isotopes; Nuclear and plasma sciences; Optical attenuators; Performance evaluation; Propagation losses;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.354415
  • Filename
    4179529