• DocumentCode
    471691
  • Title

    Use of the Finite Element Method to Assess Impact of Current on Forearm and Wrist During an Electrical Accident

  • Author

    Morse, Michael S. ; Morse, Jennifer S.

  • Author_Institution
    Dept. of Electr. Eng., Univ. of San Diego, CA
  • fYear
    2006
  • fDate
    Aug. 30 2006-Sept. 3 2006
  • Firstpage
    2377
  • Lastpage
    2379
  • Abstract
    Using geometric primitives, a three dimensional finite element model has been developed to assess the pathway followed by electric current during an electrical accident assuming the entry point for the current was on one hand. Results indicate that the area where the risk of soft tissue injury is greatest is in the wrist region. Current entry on the palm or finger fronts was found to be more likely to yield injury to the median nerve than an entry point on the back of the hand. The lesser injury is theorized to result because of current shielding of the nerve by bone
  • Keywords
    bioelectric phenomena; biological effects of fields; finite element analysis; neurophysiology; bone; carpal tunnel syndrome; current impact assessment; current shielding; electric shock; electrical accident; electrical injury; median nerve; soft tissue injury risk; three dimensional finite element method; Contacts; Current density; Electrical accidents; Fingers; Finite element methods; Geometry; Humans; Injuries; Solid modeling; Wrist; Carpal tunnel; carpal tunnel syndrome; electric shock; electrical injury; finite element method; median nerve;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1557-170X
  • Print_ISBN
    1-4244-0032-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2006.260356
  • Filename
    4462272