DocumentCode
471691
Title
Use of the Finite Element Method to Assess Impact of Current on Forearm and Wrist During an Electrical Accident
Author
Morse, Michael S. ; Morse, Jennifer S.
Author_Institution
Dept. of Electr. Eng., Univ. of San Diego, CA
fYear
2006
fDate
Aug. 30 2006-Sept. 3 2006
Firstpage
2377
Lastpage
2379
Abstract
Using geometric primitives, a three dimensional finite element model has been developed to assess the pathway followed by electric current during an electrical accident assuming the entry point for the current was on one hand. Results indicate that the area where the risk of soft tissue injury is greatest is in the wrist region. Current entry on the palm or finger fronts was found to be more likely to yield injury to the median nerve than an entry point on the back of the hand. The lesser injury is theorized to result because of current shielding of the nerve by bone
Keywords
bioelectric phenomena; biological effects of fields; finite element analysis; neurophysiology; bone; carpal tunnel syndrome; current impact assessment; current shielding; electric shock; electrical accident; electrical injury; median nerve; soft tissue injury risk; three dimensional finite element method; Contacts; Current density; Electrical accidents; Fingers; Finite element methods; Geometry; Humans; Injuries; Solid modeling; Wrist; Carpal tunnel; carpal tunnel syndrome; electric shock; electrical injury; finite element method; median nerve;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
Conference_Location
New York, NY
ISSN
1557-170X
Print_ISBN
1-4244-0032-5
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/IEMBS.2006.260356
Filename
4462272