• DocumentCode
    471888
  • Title

    Semi-Automated Intra-Operative Fluoroscopy Guidance For Osteotomy And External-Fixator

  • Author

    Lin, Hong ; Samchukov, Mikhail L. ; Birch, John G. ; Cherkashin, Alexander

  • Author_Institution
    Texas Scottish Rite Hosp. for Children, Dallas, TX
  • fYear
    2006
  • fDate
    Aug. 30 2006-Sept. 3 2006
  • Firstpage
    3811
  • Lastpage
    3814
  • Abstract
    This paper outlines a semi-automated intra-operative fluoroscopy guidance and monitoring approach for osteotomy and external-fixator application in orthopedic surgery. Intra-operative Guidance module is one component of the "LegPerfect Suite" developed for assisting the surgical correction of lower extremity angular deformity. The Intra-operative Guidance module utilizes information from the preoperative surgical planning module as a guideline to overlay (register) its bone outline semi-automatically with the bone edge from the real-time fluoroscopic C-Arm X-Ray image in the operating room. In the registration process, scaling factor is obtained automatically through matching a fiducial template in the fluoroscopic image and a marker in the module. A triangle metal plate, placed on the operating table is used as fiducial template. The area of template image within the viewing area of the fluoroscopy machine is obtained by the image processing techniques such as edge detection and Hough transformation to extract the template from other objects in the fluoroscopy image. The area of fiducial template from fluoroscopic image is then compared with the area of the marker from the planning so as to obtain the scaling factor. After the scaling factor is obtained, the user can use simple operations by mouse to shift and rotate the preoperative planning to overlay the bone outline from planning with the bone edge from fluoroscopy image. In this way osteotomy levels and external fixator positioning on the limb can guided by the computerized preoperative plan
  • Keywords
    Hough transforms; bone; diagnostic radiography; edge detection; image registration; medical image processing; orthopaedics; surgery; Hough transformation; LegPerfect Suite; bone; computerized preoperative plan; edge detection; fiducial template; image processing technique; image registration; lower extremity angular deformity; metal plate; orthopedic surgery; osteotomy; preoperative surgical planning module; real-time fluoroscopic C-Arm X-Ray image; semiautomated intra-operative fluoroscopy guidance; Bones; Image edge detection; Image processing; Image registration; Mice; Monitoring; Process planning; Surgery; Surges; X-ray imaging; Hough transformation; LegPerfect Suite; Preoperative planning; external-fixator; fluoroscopic image; image registration; intra-operative guidance; osteotomy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1557-170X
  • Print_ISBN
    1-4244-0032-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2006.259897
  • Filename
    4462630