Magnet demagnetization observation or permanent magnet synchronous motor
Author
Xi, Xiao ; Changming, Chen ; Meng, Zhang
Author_Institution
Dept. of Electr. Eng., Tsinghua Univ., Beijing
fYear
2008
fDate
17-20 Oct. 2008
Firstpage
3216
Lastpage
3219
Abstract
Accurate information of rotor permanent magnet field is needed in permanent magnet synchronous motor(PMSM) control, but this information is variable under demagnetization conditions, such as high temperature or peak current. Nonsinusoidal flux density distribution caused by demagnetization induces to torque ripple, which degrades the PMSM drive performance. To estimate flux magnitude, a Kalman filter is built by using stator current and PM flux as state variables. The estimation method can accurately track the diversity of permanent flux and is robust to motorspsila parameters. The flux linkage is represented by means of Fourier series expansion, and the observe method is used for the online detection demagnetization of PMSM. Experimental evaluations of flux linkage are carried out on a DSP-controlled PMSM drive platform. Test results obtained demonstrate the effect of the proposed method.
Keywords
Fourier series; Kalman filters; demagnetisation; permanent magnet motors; stators; synchronous motor drives; DSP-controlled PMSM drive; Fourier series expansion; Kalman filter; magnet demagnetization; nonsinusoidal flux density distribution; permanent magnet synchronous motor; rotor permanent magnet field; stator current; torque ripple; Couplings; Degradation; Demagnetization; Drives; Magnetic flux; Magnetic variables control; Permanent magnet motors; Rotors; Temperature control; Torque;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
Conference_Location
Wuhan
Print_ISBN
978-1-4244-3826-6
Electronic_ISBN
978-7-5062-9221-4