Study on fault-synchronizing current and electromagnetic torque of powerformer
Author
Zhiqiang, Zhang ; Baojun, GE ; Dajun, Tao ; Yanling, LV
Author_Institution
Collage of Electr. & Electron. Eng., Harbin Univ. of Sci. & Technol., Harbin
fYear
2008
fDate
17-20 Oct. 2008
Firstpage
4037
Lastpage
4039
Abstract
This paper presents a numerical method to analyze the complex process of fault synchronizing parallel operation. A set of state-space equations is adopted to calculate the transient current and electromagnetic torque of the process. A new type of high-voltage synchronous generator is introduced for fault synchronizing parallel operation.
Keywords
fault diagnosis; numerical analysis; synchronous generators; electromagnetic torque; fault synchronizing parallel operation; fault-synchronizing current; high-voltage synchronous generator; numerical method; powerformer; state-space equations; transient current; Accidents; Circuit faults; Equations; Frequency synchronization; Power generation; Power transformer insulation; Shafts; Synchronous generators; Torque; Transmission line matrix methods;