• DocumentCode
    501865
  • Title

    Contributions to standardization of Transmission Line Pulse testing methodology

  • Author

    Keppens, B. ; De Heyn, V. ; Natarajan Iyer, M. ; Groeseneken, G.

  • Author_Institution
    STDI-TRY, Imec vzw, Leuven, Belgium
  • fYear
    2001
  • fDate
    11-13 Sept. 2001
  • Firstpage
    456
  • Lastpage
    462
  • Abstract
    When characterizing semiconductor components to determine their ESD robustness using a transmission line pulse test system, there is no universally accepted standard procedure for performing the test available at present. In this paper, we address this issue whereby we study the impact of the following TLP characterization related variables: failure criterion, influence of stress step-size and cumulative stress effects. We show that the failure criterion, `any increase in leakage´, yields the most reproducible and reliable results in the devices tested.
  • Keywords
    electrostatic discharge; semiconductor device reliability; semiconductor device testing; stress effects; transmission lines; ESD robustness; TLP failure criterion; cumulative stress effect; semiconductor component; semiconductor device reliability; stress step-size influence; transmission line pulse testing; Current measurement; Electrostatic discharge; Leakage current; Performance evaluation; Protection; Pulse measurements; Standardization; Testing; Time measurement; Transmission lines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium, 2001. EOS/ESD '01.
  • Conference_Location
    Portland, OR
  • Print_ISBN
    978-1-5853-7039-9
  • Electronic_ISBN
    978-1-5853-7039-9
  • Type

    conf

  • Filename
    5254935