• DocumentCode
    513587
  • Title

    Application of GTEM cell in calibration of Electric Field Monitoring System

  • Author

    Suresh, K.R. ; Shah, Sandhya ; Sunitha, B. ; Nalini, B.R.

  • Author_Institution
    Bharat Electron. Ltd., Bangalore, India
  • fYear
    2006
  • fDate
    23-24 Feb. 2006
  • Firstpage
    321
  • Lastpage
    323
  • Abstract
    Radiated susceptibility test is a very important for electronic equipment to ensure that they operate without any degradation in performance when exposed to high RF fields. The generation of RF fields accurately is essential during performing this test. Normally RF field probes are used to measure the field levels. Any electronic measuring device tends to drift over a period of time. Calibration of this type of probes is of paramount importance to ensure that the fields generated and measured are accurate. This paper brings out an application of GTEM cell for calibrating E - Field probes in the frequency range of 10 KHz to 1 GHz.
  • Keywords
    TEM cells; calibration; electric field measurement; electronic equipment testing; GTEM cell; RF field probes; electric field monitoring system calibration; electronic equipment; frequency 10 kHz to 1 GHz; measurement accuracy; radiated susceptibility test; Calibration; Degradation; Electronic equipment; Electronic equipment testing; Monitoring; Performance evaluation; Probes; Radio frequency; TEM cells; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    ElectroMagnetic Interference and Compatibility (INCEMIC), 2006 Proceedings of the 9th International Conference on
  • Conference_Location
    Bangalore
  • Print_ISBN
    978-1-4244-5203-3
  • Type

    conf

  • Filename
    5419723