• DocumentCode
    535998
  • Title

    Inverse Synthetic Aperture Radar Imaging at Low Signal-to-noise Ratio

  • Author

    Ju, Yanwei ; Yu, Li ; Wang, Yang ; Chu, Xiaobin

  • Author_Institution
    Nanjing Res. Inst. of Electron. Technol., Nanjing, China
  • Volume
    2
  • fYear
    2010
  • fDate
    23-24 Oct. 2010
  • Firstpage
    106
  • Lastpage
    110
  • Abstract
    Inverse synthetic aperture radar (ISAR) imaging at low SNR ratio is not resolved completely. The SNR increases in time-frequency domain over the one in the time or the frequency domain alone both theoretically and numerically. This shows advantage of time-frequency analysis technique for ISAR imaging at low SNR. The reassigned Gabor spectrogram time-frequency distribution is proposed for ISAR imaging at low SNR. Finally, the real data demonstrated the validity of the method proposed.
  • Keywords
    radar imaging; synthetic aperture radar; time-frequency analysis; inverse synthetic aperture radar imaging; reassigned Gabor spectrogram; signal-to-noise ratio; time-frequency domain; Imaging; Radar imaging; Signal resolution; Signal to noise ratio; Time frequency analysis; Transforms; ISAR imaging; Low Signal-to-noise Ratio; Reassigned Gabor spectrogram time-frequency distribution;