• DocumentCode
    544219
  • Title

    Extracellular measurement of acetylcholine receptor function in microcircuit-coupled myoblasts

  • Author

    Quong, Judy N. ; Stenger, David A. ; Bryant, Howard ; Fare, Thomas L.

  • Author_Institution
    George Washington Univ., Washington, DC, USA
  • Volume
    1
  • fYear
    1992
  • fDate
    Oct. 29 1992-Nov. 1 1992
  • Firstpage
    115
  • Lastpage
    116
  • Abstract
    An electrophysiological measurement principle for long-term, non-invasive monitoring of acetylcholine receptor function is described. Measurements depend on the ability to record agonist-induced depolarizations of clonal myoblasts that form high impedance seals with extracellular microcircuit electrodes. The extracellular potentials are shown to be completely eliminated by α-bungarotoxin. The technique appears promising for a variety of non-invasive electrophysiological biosensing applications.
  • Keywords
    bioelectric potentials; biomedical measurement; biomembrane transport; biosensors; electric sensing devices; microelectrodes; molecular biophysics; patient monitoring; proteins; toxicology; α-bungarotoxin; acetylcholine receptor function; agonist-induced depolarization; clonal myoblasts; electrophysiological measurement principle; extracellular measurement; extracellular microcircuit electrodes; extracellular potentials; high impedance seals; long term noninvasive monitoring; microcircuit-coupled myoblasts; noninvasive electrophysiological biosensing; Biosensors; Facsimile;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE
  • Conference_Location
    Paris
  • Print_ISBN
    0-7803-0785-2
  • Electronic_ISBN
    0-7803-0816-6
  • Type

    conf

  • DOI
    10.1109/IEMBS.1992.5760883
  • Filename
    5760883