DocumentCode
544772
Title
Wavelet analysis of evoked potentials
Author
Thakor, N.V. ; Rix, H. ; Caminal, P.
Author_Institution
The Johns Hopkins University School of Medicine, Baltimore, MD, USA
Volume
6
fYear
1992
fDate
Oct. 29 1992-Nov. 1 1992
Firstpage
2446
Lastpage
2447
Abstract
Ischemic neurological injury has been shown to alter the temporal and spectral features of somatosensory evoked potentials. Multiresolution wavelet analysis is employed in this study to quantitate such injury-related changes. EP signals are decomposed into constituent "coarse" and "detail" components. In the frequency domain, these components correspond to the lowpass filtered and bandpass filtered signals, respectively. Somatosensory evoked potentials recorded during acute cerebral hypoxia and during subsequent recovery are analyzed. Changes in the shape of the coarse components are shown to be sensitive indicators of ischemia. Amplitude trends of the coarse and the detail components are also shown to follow the ischemic event and subsequent recovery.
Keywords
Adaptation model; Biological system modeling; Biomedical monitoring; Brain modeling; Monitoring; Signal resolution;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE
Conference_Location
Paris, France
Print_ISBN
0-7803-0785-2
Electronic_ISBN
0-7803-0816-6
Type
conf
DOI
10.1109/IEMBS.1992.5761533
Filename
5761533
Link To Document