• DocumentCode
    571987
  • Title

    POS use efficiency in multimodule accelerator with self-magnetic insulation

  • Author

    Zajivikhin, V.V.

  • Author_Institution
    TRINITI, Troitsk, Russia
  • Volume
    1
  • fYear
    1992
  • fDate
    25-29 May 1992
  • Firstpage
    592
  • Lastpage
    597
  • Abstract
    The top value of power enhancement and voltage multiplication in inductive store system with the plasma opening switch (POS) have been studied. Different kinds of loads have been considered. It has been shown that electron losses in vacuum transmission line (VTL) with self-magnetic insulation (SMI) can essentialy change the output pulse parameters. Among issues examined are also the effects of the POS on synchronization condition of the multimodule generator and on the optimum liner parameters used at Angara-5 facility.
  • Keywords
    electron accelerators; plasma switches; transmission lines; Angara-5 facility; POS use efficiency; SMI; VTL; electron losses; inductive storage system; multimodule accelerator; multimodule generator; optimum liner parameters; output pulse parameters; plasma opening switch; power enhancement; self magnetic insulation; vacuum transmission line; voltage multiplication; Generators; Impedance; Inductance; Leakage current; Load modeling; Mathematical model; Switches;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High-Power Particle Beams, 1992 9th International Conference on
  • Conference_Location
    Washington,DC
  • Print_ISBN
    000-0-0000-0000-0
  • Type

    conf

  • Filename
    6306543