• DocumentCode
    590116
  • Title

    Shielding effectiveness calculation of metallic enclosure with aperture array

  • Author

    Yang Cui ; Zijing Qiu ; Xiaonan Zhao

  • Author_Institution
    China Ship Dev. & Design Centre(CSDDC), Wuhan, China
  • fYear
    2012
  • fDate
    22-26 Oct. 2012
  • Firstpage
    1090
  • Lastpage
    1094
  • Abstract
    As an equipment protecting and isolating electromagnetic interference, the shielding enclosure always needs aperture on the wall which destroys the completeness of the enclosure. In this article, the transmission line method (TL method) is applied in the electromagnetic shielding effectiveness (SE) of a metallic enclosure with aperture array. We analysed the situation of incident arbitrary polarized electromagnetic wave, the number and arrangement of aperture array, and give the equivalent calculation expression when the number of side holes, length of aperture arrays ranging. At last, we give the recommendations of the relationship between the hole size and the distance between apertures by simulation. Good agreement are obtained between simulated results and calculated results.
  • Keywords
    electromagnetic interference; electromagnetic shielding; transmission lines; TL method; aperture array; electromagnetic interference; electromagnetic shielding effectiveness; equipment protection; incident arbitrary polarized electromagnetic wave; metallic enclosure; shielding effectiveness calculation; transmission line method; Apertures; Arrays; Cavity resonators; Electric fields; Electromagnetic scattering; Electromagnetic waveguides; Impedance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas, Propagation & EM Theory (ISAPE), 2012 10th International Symposium on
  • Conference_Location
    Xian
  • Print_ISBN
    978-1-4673-1799-3
  • Type

    conf

  • DOI
    10.1109/ISAPE.2012.6408965
  • Filename
    6408965