• DocumentCode
    618835
  • Title

    An emulation of data concentrator units conformed to DLMS-HDLC protocols

  • Author

    Limphapayom, Siwarat ; Pora, Wanchalerm

  • Author_Institution
    Dept. of Electr. Eng., Chulalongkorn Univ., Bangkok, Thailand
  • fYear
    2013
  • fDate
    15-17 May 2013
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    In the advanced metering infrastructure, there are many data communication standards. In this paper, a PC-based data concentrator unit employs the DLMS/COSEM standard with HDLC as the data-link layer over a physical GSM modem. Examples of data readings from DLMS smart meters are shown in IV. The readings include load profile, billing data and event log.
  • Keywords
    cellular radio; metering; modems; smart meters; DLMS smart meters; DLMS-COSEM standard; DLMS-HDLC protocols; PC-based data concentrator unit; advanced metering infrastructure; billing data; data communication standards; data link layer; data readings; event log; load profile; physical GSM modem; Data communication; Electricity; Encoding; GSM; Modems; Protocols; Standards; DCU; DLMS; GSM; HDLC;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON), 2013 10th International Conference on
  • Conference_Location
    Krabi
  • Print_ISBN
    978-1-4799-0546-1
  • Type

    conf

  • DOI
    10.1109/ECTICon.2013.6559622
  • Filename