• DocumentCode
    636518
  • Title

    Neuromechanical sensor fusion yields highest accuracies in predicting ambulation mode transitions for trans-tibial amputees

  • Author

    Tkach, Dennis C. ; Hargrove, Levi J.

  • Author_Institution
    Center for Bionic Med. at the Rehabilitation Inst. of Chicago, Chicago, IL, USA
  • fYear
    2013
  • fDate
    3-7 July 2013
  • Firstpage
    3074
  • Lastpage
    3077
  • Abstract
    Advances in battery and actuator technology have enabled clinical use of powered lower limb prostheses such as the BiOM Powered Ankle. To allow ambulation over various types of terrains, such devices rely on built-in mechanical sensors or manual actuation by the amputee to transition into an operational mode that is suitable for a given terrain. It is unclear if mechanical sensors alone can accurately modulate operational modes while voluntary actuation prevents seamless, naturalistic gait. Ensuring that the prosthesis is ready to accommodate new terrain types at first step is critical for user safety. EMG signals from patient´s residual leg muscles may provide additional information to accurately choose the proper mode of prosthesis operation. Using a pattern recognition classifier we compared the accuracy of predicting 8 different mode transitions based on (1) prosthesis mechanical sensor output (2) EMG recorded from residual limb and (3) fusion of EMG and mechanical sensor data. Our findings indicate that the neuromechanical sensor fusion significantly decreases errors in predicting 10 mode transitions as compared to using either mechanical sensors or EMG alone (2.3±0.7% vs. 7.8±0.9% and 20.2±2.0% respectively).
  • Keywords
    electromyography; medical signal processing; muscle; neurophysiology; pattern recognition; prosthetics; sensor fusion; signal classification; BiOM Powered Ankle; EMG recording; EMG signals; actuator technology; ambulation mode transitions; battery; built-in mechanical sensors; manual actuation; naturalistic gait; neuromechanical sensor fusion; operational mode; patient residual leg muscles; pattern recognition classifier; powered lower limb prostheses; prosthesis mechanical sensor output; prosthesis operation; trans-tibial amputees; user safety; voluntary actuation; Accuracy; Electrodes; Electromyography; Legged locomotion; Mechanical sensors; Muscles; Prosthetics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
  • Conference_Location
    Osaka
  • ISSN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2013.6610190
  • Filename
    6610190