DocumentCode
636977
Title
Accuracy improvement in Cranio-Maxillofacial soft tissue simulation using a muscle embedded meshing approach
Author
Shahim, K. ; Goksel, O. ; Jurgens, P. ; Reyes, Mauricio
Author_Institution
Inst. for Surg. Technol. & Biomech. (ISTB), Univ. of Bern, Bern, Switzerland
fYear
2013
fDate
3-7 July 2013
Firstpage
7156
Lastpage
7159
Abstract
In the presented paper, we propose to improve the state-of-the-art approach for Cranio-Maxillofacial (CMF) soft tissue simulation by considering a new image-based meshing approach that accurately models the interface between different tissue types. The proposed approach has been initially evaluated on soft tissue deformations of four patients undergoing CMF surgery using post-operative CT scans. The results indicate improved prediction and robustness of the surgical planning outcome when compared to the state-of-the-art method while decreasing the simulation time.
Keywords
biological tissues; biomechanics; deformation; medical computing; simulation; surgery; CMF soft tissue simulation; CMF surgery; cranio-maxillofacial soft tissue simulation; image based meshing approach; muscle embedded meshing approach; post operative CT scan; soft tissue deformation; soft tissue simulation accuracy improvement; surgical planning outcome; Accuracy; Biological tissues; Computational modeling; Computed tomography; Material properties; Muscles; Surgery;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE
Conference_Location
Osaka
ISSN
1557-170X
Type
conf
DOI
10.1109/EMBC.2013.6611208
Filename
6611208
Link To Document