• DocumentCode
    653536
  • Title

    Sinusoidal, triangular or square alternating voltages neutralization of electrostatics charges on the surface of polypropylene nonwoven fabric

  • Author

    Yahiaoui, Belkacem ; Megherbi, Mohammed ; Tabti, Belaid ; Dascalescu, Lucian

  • Author_Institution
    Univ. A. Mira, Bejaia, Algeria
  • fYear
    2013
  • fDate
    6-11 Oct. 2013
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    The most widely-used techniques for neutralizing the static charge at the surface of insulating bodies make use of the bipolar ions generated in an AC corona discharge. The aim of the present work is to evaluate the efficiency of the neutralization achieved with a corona electrode energized from a generator of sinusoidal, triangular and square AC voltages of various amplitudes and frequencies. The experiments were performed on 120 mm × 90 mm samples cut from the same non-woven polypropylene (PP) fabric. The samples were charged for 10 s, in ambient air, using a triode-type corona electrode system of positive polarity. The neutralization was performed 300 s after the charging process, with the samples moving at constant speed (3 cm/s) in the AC corona discharge zone. The electric potential distribution at the surface of the samples was measured with an electrostatic voltmeter (model 3450, Trek Inc., Medina, NY). The efficiency of the neutralization was evaluated by calculating the inverse ratio between the maximum absolute values of the potential before and just after the neutralization. The amount and the polarity of the residual charge after neutralization depend on the frequency, amplitude and type of AC voltage. The results show that an excellent neutralization can be obtained for any of the three wave-shapes of AC voltage, at industrial frequency (i.e., 50 Hz) by varying the amplitude of the offset.
  • Keywords
    corona; fabrics; plasma probes; plasma transport processes; polymer fibres; surface charging; triodes; AC corona discharge; bipolar ions; electrostatic voltmeter; electrostatics charges; frequency 50 Hz; inverse ratio; polypropylene nonwoven fabric; square alternating voltage neutralization; time 10 s; time 300 s; triangular alternating voltages neutralization; triode-type corona electrode system; Corona; Electric potential; Electrodes; Finite volume methods; Insulation; Neutralization; Surface treatment; Voltage measurement; charge neutralization; corona discharge; fibrous electrets; surface potential distribution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Society Annual Meeting, 2013 IEEE
  • Conference_Location
    Lake Buena Vista, FL
  • ISSN
    0197-2618
  • Type

    conf

  • DOI
    10.1109/IAS.2013.6682445
  • Filename
    6682445