Abstract
In order to evaluate the operating characteristics of RTV anti-pollution flashover coatings used in Guangdong Province, a series of experiments and tests were carried out on RTV coatings operating in different natural environments with operating periods ranging from 3 years to 8 years. The research results showed that the appearance of coatings were affected by operating years, pollution areas, pollution sources and methods of suspension. There was different hydrophobicity on different location, and the weakest hydrophobicity located on the outer part of upper shed. The hydrophobicity of coatings was affected by the types of pollution sources. The flashover voltage of coatings was directly affected by the hydrophobicity distribution. There was a certain correspondence between the appearance and the flashover voltage of anti-pollution flashover coatings.
Keywords
flashover; hydrophobicity; insulators; Guangdong province; RTV antipollution flashover coatings; antipollution flashover coatings; coating appearance; coating flashover voltage; coating hydrophobicity; hydrophobicity distribution; natural environment; operating years; pollution areas; pollution sources; suspension method; Coatings; Flashover; Insulators; Pollution; Strain; Surface contamination; Surface treatment; RTV anti-pollution flashover coatings; appearance; hydrophobicity; operating characteristics; pollution flashover voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena (CEIDP), 2013 IEEE Conference on
Conference_Location
Shenzhen
Type
conf
DOI
10.1109/CEIDP.2013.6747075
Filename
6747075
Link To Document