• DocumentCode
    686866
  • Title

    K-edge imaging with a photon counting CT system

  • Author

    Matsumoto, Morio ; Kaibuki, Futoshi ; Ogawa, Koichi

  • Author_Institution
    Grad. Sch. of Eng., Hosei Univ., Tokyo, Japan
  • fYear
    2013
  • fDate
    Oct. 27 2013-Nov. 2 2013
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    The purpose of our research is to measure the amount of contrast agents used in x-ray CT accurately. The use of contrast agents such as gold nano-particles enables molecular imaging with the x-ray CT system. To realize an energy discriminating measurement, we have developed a photon counting detector with a CdTe semiconductor that is able to measure x-rays with the count rate of 107 cps/mm2 with four energy windows. In order to measure the concentration ratio of the contrast agent, we used a k-edge imaging technique. The materials used in this experiment were Au-colloid, Pt-colloid and gadolinium solution. The results of experiments showed linearity between the linear attenuation coefficients of k-edge images that were calculated using the two energy bins near each k-edge, and the concentration ratios of the contrast agents. For Au-colloid, the measurement error was less than 4 %, while for the gadolinium agent, the accuracy depended on the window width. This was caused by the electrical noise in the lower energy window and the beam-hardening effect in the measured data.
  • Keywords
    II-VI semiconductors; cadmium compounds; colloids; computerised tomography; gadolinium; gold; measurement errors; nanoparticles; photon counting; platinum; wide band gap semiconductors; Au colloid; CdTe semiconductor; CdTe-Gd; CdTe-Pt; Pt colloid; X-ray computerised tomography; beam-hardening effect; contrast agent concentration ratio; electrical noise; energy discriminating measurement; energy windows; gadolinium solution; gold nanoparticles; k-edge imaging; linear attenuation coefficients; measurement error; molecular imaging; photon counting computerised tomography system; photon counting detector; window width; Attenuation; Detectors; Energy measurement; Image reconstruction; Materials; Photonics; Semiconductor device measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
  • Conference_Location
    Seoul
  • Print_ISBN
    978-1-4799-0533-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2013.6829299
  • Filename
    6829299