• DocumentCode
    687269
  • Title

    The 3-D elemental imaging method research based D elemental imaging method research based D elemental imaging method research based D elemental imaging method research based D elemental imaging method research based D elemental imaging method research bas

  • Author

    Yigang Yang ; Yuanjing Li

  • Author_Institution
    Dept. of Eng. Phys., Tsinghua Univ., Beijing, China
  • fYear
    2013
  • fDate
    Oct. 27 2013-Nov. 2 2013
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    A photoneutron based analysis system, which is composed of a 7 MeV LINAC, a 2.6 kg beryllium photoneutron convertor and a NaI(Tl) detector array, has been setup to register the 2-dimensional elemental distributions of the inspected materials. 2-dimensional images of 4 elements, hydrogen, nitrogen, chlorine and iron, could be acquired simultaneously in once scanning to indicate the potential existence of concealed contrabands. But the overlap between different materials of the elemental distribution may disturb the identification of contrabands because their elemental concentrations will be mixed with innocent materials. To remove the overlap effect of different materials, 3-dimensional elemental imaging technique is researched in this paper. By using two opposite-placed detector arrays of 8 NaI(Tl) detectors respectively, two images for 4 elements are measured. An algorithm is developed to fuse the two images together to form a 3-dimensional image for each element by comparing the count rates and footprints of the element measured by two detector arrays. The preliminary result shows that the spatial resolution of hydrogen, nitrogen, chlorine and iron could be 20 cm * 40 cm * 20 cm. The overlap of different materials then could be removed and the capability of contrabands identification could be enhanced.
  • Keywords
    chlorine; convertors; hydrogen; iron; linear accelerators; nitrogen; nuclear materials safeguards; sodium compounds; solid scintillation detectors; thallium; 2-dimensional elemental distributions; 3-D elemental imaging method research; 3-dimensional elemental imaging technique; LINAC; NaI(TI) detector array; algorithm development; beryllium photoneutron convertor; chlorine 2-dimensional image; chlorine spatial resolution; contraband identification capability; elemental concentrations; hydrogen 2-dimensional image; hydrogen spatial resolution; innocent materials; inspected materials; iron 2-dimensional image; iron spatial resolution; material elemental distribution overlap; material overlap removal; measured element count rates; measured element footprints; nitrogen 2-dimensional image; nitrogen spatial resolution; opposite-placed detector arrays; photoneutron based analysis system; potential concealed contraband existence; Hydrogen; Iron; Nitrogen; Photonics; Spatial resolution; Three-dimensional displays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
  • Conference_Location
    Seoul
  • Print_ISBN
    978-1-4799-0533-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2013.6829717
  • Filename
    6829717