  • Abstract
    Due to the electromagnetic radiation interference, it is recommended to prohibit using mobile stations in the area of industrial buildings in the power plant. While pagers are successfully applied, there are many drawbacks for the pagers in the nuclear power plant. This paper proposes a working method for the mobile station in the nuclear power plant. By the way of simple improvements in the mobile station and the base station, the defects of the pagers are overcome, the issue of prohibiting using mobile stations in area of industrial building in the nuclear power plant is solved and potential safety problems due to human factors for not turning off mobile stations are eliminated.
  • Keywords
    fission reactor safety; nuclear power stations; radiation protection; electromagnetic radiation interference; industrial buildings; nuclear power plant mobile station; nuclear power plant safety problems; pager defects; Base stations; Buildings; Computer architecture; Interference; Mobile communication; Power generation; Safety; base station; mobile station; nuclear power plant; pilot signal; working method;