• DocumentCode
    729857
  • Title

    Assessment of pollutants emission of two residential micro-CHP systems

  • Author

    Mongibello, L. ; Bianco, N. ; Caliano, M. ; Graditi, G.

  • Author_Institution
    Italian Nat. Agency for New Technol., Energy & Sustainable Econ. Dev., Portici Res. Cente, Portici, Italy
  • fYear
    2015
  • fDate
    16-18 June 2015
  • Firstpage
    290
  • Lastpage
    296
  • Abstract
    In this work the characterization of pollutants emission of two different commercial prime movers producing electricity and heat during the cold season for a multi-apartment housing situated in Italy is addressed. In particular, an internal combustion engine and a microturbine, both fed by natural gas, have been analyzed separately. For each prime mover, the emission of CO2, CO and NOx resulting from two different optimized operation modes are reported and discussed. The results show that the micro-CHP system with the internal combustion engine as prime mover involves a marked augmentation of dangerous CO and NOX emissions on a local scale.
  • Keywords
    air pollution control; cogeneration; internal combustion engines; Italy; electricity production; internal combustion engine; microturbine; natural gas; pollutant emission Assessment; residential micro-CHP system; Boilers; Cogeneration; Natural gas; Production; Resistance heating; Thermal energy; global CO2 emissions; local CO and NOX emissions; micro-CHP systems; operation schedule optimization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Clean Electrical Power (ICCEP), 2015 International Conference on
  • Conference_Location
    Taormina
  • Type

    conf

  • DOI
    10.1109/ICCEP.2015.7177638
  • Filename
    7177638