• DocumentCode
    73800
  • Title

    Modified Charge Amplifier for Stray Immune Capacitance Measurements

  • Author

    Oven, Robert

  • Author_Institution
    Sch. of Eng. & Digital Arts, Univ. of Kent Canterbury, Canterbury, UK
  • Volume
    63
  • Issue
    7
  • fYear
    2014
  • fDate
    Jul-14
  • Firstpage
    1748
  • Lastpage
    1752
  • Abstract
    It is shown theoretically and by experimentation that the ac stray immune capacitance meter based on the charge amplifier circuit can be modified to reduce the effects of the parasitic capacitance across the feedback capacitor. This is achieved by simply introducing a unity gain buffer amplifier within the circuit loop.
  • Keywords
    buffer circuits; capacitance measurement; capacitive sensors; capacitors; feedback amplifiers; AC stray immune capacitance measurement; AC stray immune capacitance meter; circuit loop; feedback capacitor; modified charge amplifier circuit; parasitic capacitance effect reduction; unity gain buffer; Bandwidth; Capacitance measurement; Capacitors; Immune system; Impedance; Parasitic capacitance; Capacitance measurement; capacitive sensor; charge amplifier; operational amplifier; parasitic capacitance; parasitic capacitance.;