DocumentCode
747163
Title
Tuning numeric parameters to troubleshoot a telephone-network loop
Author
Merz, Christopher J. ; Pazzani, M.J. ; Danyluk, Andrea Pohoreckyi
Author_Institution
California Univ., Irvine, CA, USA
Volume
11
Issue
1
fYear
1996
fDate
2/1/1996 12:00:00 AM
Firstpage
44
Lastpage
49
Abstract
The Nynex Max expert system analyzes the result of an automated electric test on a telephone line and determines the type of problem. However, tuning the system´s parameter values can be difficult. The Opti-Max system can automatically set these parameters by analyzing decisions made by experts who troubleshoot problems
Keywords
automatic test equipment; diagnostic expert systems; telecommunication computing; telecommunication equipment testing; telecommunication network reliability; telephone networks; Nynex Max expert system; Opti-Max system; automated electric test; numeric parameter tuning; telephone line; telephone-network loop troubleshooting; Automatic testing; Central office; Diagnostic expert systems; Expert systems; Humans; Knowledge based systems; Performance evaluation; System testing; Telephony; Voltage;
fLanguage
English
Journal_Title
IEEE Expert
Publisher
ieee
ISSN
0885-9000
Type
jour
DOI
10.1109/64.482957
Filename
482957
Link To Document