DocumentCode
750519
Title
Performance under design and test of the 20500 HP TEAAC synchronous motors for the Shaybah project in the Rub-Al-Khali desert, Saudi Arabia
Author
Vouk, Alfred O.
Author_Institution
Saudi Aramco, Dhahran, Saudi Arabia
Volume
39
Issue
4
fYear
2003
Firstpage
1177
Lastpage
1180
Abstract
In July 1998, a large oil company successfully started up the ambitious Shaybah oil production project. The largest motors that were procured for this undertaking had to be designed to operate in one of the most forbidding environments on earth. The project location in the Saudi Arabian Rub-Al-Khali (Empty Quarter) desert experiences daily heat extremes in excess of 50 °C, extensive periods of wind-borne dust, and exposure to relentless solar radiation. Totally enclosed air-to-air cooling (TEAAC) was and continues to be specified for all large motors. The motor standards that were applied during procurement were based upon NEMA MG-1, which clearly stated that for operation in an ambient that exceeds 50 °C, the allowable temperature rise is to be reduced by 20 °C. This paper reviews the performance issues that were raised during design and test in order to meet the requirements of this very difficult TEAAC application. Engineering tradeoffs that had to be thoroughly justified by both the motor manufacturer and the motor user are also highlighted.
Keywords
cooling; machine testing; oil technology; synchronous motors; 20500 hp; NEMA MG-1; Rub-Al-Khali desert; Saudi Arabia; Shaybah project; TEAAC synchronous motors; daily heat extremes; oil company; solar radiation; totally enclosed air-to-air cooling; wind-borne dust; Cooling; Earth; Petroleum; Procurement; Production; Solar heating; Solar radiation; Synchronous motors; Temperature; Testing;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.2003.813741
Filename
1215452