• DocumentCode
    75305
  • Title

    An Optimization Method for Induction Magnetometer of 0.1 mHz to 1 kHz

  • Author

    Bin Yan ; Wanhua Zhu ; Leisong Liu ; Kai Liu ; Guangyou Fang

  • Author_Institution
    Grad. Univ. of Chinese Acad. of Sci., Beijing, China
  • Volume
    49
  • Issue
    10
  • fYear
    2013
  • fDate
    Oct. 2013
  • Firstpage
    5294
  • Lastpage
    5300
  • Abstract
    The induction magnetometer (IM) is one of the most widely used tools to measure the variation of magnetic field in space research, geophysical exploration, environment monitoring, and so on. In this work, we proposed two different kinds of optimization methods for an IM in the frequency range of 0.1 mHz to 1 kHz; the first is for a known core and the other is for a limited IM´s volume. The optimum IM we designed, with weight less than 3 kg, diameter 45 mm, length 850 mm, and 1Hz noise level 0.2 pT/√Hz, made a new record of IM for the Magnetotelluric (MT) method and was beneficial to those in the MT field working in oil and mineral explorations. The experimental results of the optimum IM fully confirm the theoretical optimization.
  • Keywords
    magnetic cores; magnetic noise; magnetometers; magnetometry; magnetotellurics; optimisation; IM volume; MT method; environment monitoring; frequency 0.1 mHz to 1 kHz; geophysical exploration; induction magnetometer; magnetic field measurement; magnetotelluric method; mineral exploration; noise level; oil exploration; optimization method; size 45 mm; size 850 nm; space research; Magnetometers; noise; optimization method; weight control;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2013.2264821
  • Filename
    6519320