  • Abstract
    An evaluation of partial discharge detection techniques used on the Unit 3 hydroelectric generator stator windings at Tumut 1 power station in the Snowy Mountains scheme of Australia is presented. Measurements were made with an RF slot probe, Robinson ERA Model 5 detector, Ontario Hydro PDA-H detector and a recently developed partial discharge site location (PDSL) system before and after removal of coils. Good agreement was found between all methods with the PDSL system achieving high accuracy in identifying individual high discharging coil sides
  • Keywords
    hydroelectric generators; insulation testing; machine insulation; machine testing; partial discharges; probes; stators; test equipment; Australia; PDA-H detector; RF slot probe; Robinson ERA Model 5 detector; accuracy; coils; hydroelectric generator; insulation measurements; partial discharge detection techniques; partial discharge site location; power station; stator windings; Australia; Coils; Detectors; Hydroelectric power generation; Partial discharge measurement; Partial discharges; Power generation; Probes; Radio frequency; Stator windings;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/60.372564
  • Filename
    372564