• DocumentCode
    757611
  • Title

    External Clock Synchronization Plans for the GTD 3 EAX Digital Toll/Tandem

  • Author

    Schauer, Ronald E.

  • Author_Institution
    GTE Automatic Electric, Inc., Northlake, IL
  • Volume
    27
  • Issue
    7
  • fYear
    1979
  • fDate
    7/1/1979 12:00:00 AM
  • Firstpage
    988
  • Lastpage
    992
  • Abstract
    The GTD 3 EAX local clock was designed with external synchronization in mind. The initial control algorithms and control circuits required a minimum of change to incorporate the ability to maintain clock synchronization with an external timing reference. The synchronization technique used is a frequency lock method and the considerations necessary for synchronization are described in this paper.
  • Keywords
    Synchronization; Time-division switching; Circuits; Cities and towns; Clocks; Frequency synchronization; Monitoring; Phase change materials; Research and development; Switches; Switching systems; Telephony;
  • fLanguage
    English
  • Journal_Title
    Communications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0090-6778
  • Type

    jour

  • DOI
    10.1109/TCOM.1979.1094503
  • Filename
    1094503