DocumentCode
766197
Title
Performance of the TPC with micro pixel chamber readout: micro-TPC
Author
Miuchi, Kentaro ; Kubo, Hidetoshi ; Nagayoshi, Tsutomu ; Ochi, Atsuhiko ; Orito, Reiko ; Takada, Atsushi ; Tanimori, Toru ; Ueno, Masaru
Author_Institution
Dept. of Phys., Kyoto Univ., Japan
Volume
50
Issue
4
fYear
2003
Firstpage
825
Lastpage
830
Abstract
Micro-TPC, a time projection chamber (TPC) with micro pixel chamber (μ-PIC) readout, was developed for the detection of the three-dimensional (3-D) fine (∼ submillimeter) tracks of charged particles. We developed a two-dimensional position sensitive gaseous detector or the μ-PIC, with the detection area of 10×10 cm2 and 65536 anode electrodes of 400 μm pitch. We achieved the gas gain of more than 104 without any other multipliers. With the pipeline readout system specially developed for the μ-PIC, we detected X-rays at the maximum rate of 7.7 MHz. We developed a micro-TPC with the μ-PIC and 3-D tracks of electrons were detected with the micro-TPC. We also developed a prototype of the MeV gamma-ray imaging detector which is a hybrid of the micro-TPC and NaI(Tl) scintillator so that we showed that this is a promising method for the MeV gamma-ray imaging.
Keywords
gamma-ray detection; ionisation chambers; nuclear electronics; position sensitive particle detectors; readout electronics; sodium compounds; 7.7 MHz; NaI(Tl); TPC; charged particles; gamma-ray imaging; gas gain; micropixel chamber readout; pipeline readout system; position sensitive gaseous detector; time projection chamber; Anodes; Electrodes; Electrons; Nuclear imaging; Particle tracking; Pipelines; Position sensitive particle detectors; Prototypes; X-ray detection; X-ray detectors;
fLanguage