Title
Comparison between fundamental and harmonic power generation of GaAs Gunn devices at 94 GHz
Author
Curow, M.
Author_Institution
Arbeitsbereich Hochfrequenztech., Tech. Univ. Hamburg-Harburg, Germany
Volume
31
Issue
8
fYear
1995
fDate
4/13/1995 12:00:00 AM
Firstpage
656
Lastpage
657
Abstract
The Letter presents a comparison of the power generation capabilities of GaAs Gunn devices working at 94 GHz in fundamental and second harmonic modes. Based on accurate Monte-Carlo and hydrodynamic models for the active device and realistic driving forces, large-signal results indicate that, although power generation at 94 GHz in a fundamental mode is possible, harmonic operation is preferable regarding output power and resistance level, and device reliability
Keywords
Gunn devices; III-V semiconductors; Monte Carlo methods; gallium arsenide; harmonics; millimetre wave devices; semiconductor device models; semiconductor device reliability; 94 GHz; GaAs; Gunn devices; Monte-Carlo models; active device; device reliability; driving forces; fundamental mode; harmonic power generation; hydrodynamic models; large-signal results; output power; power generation capabilities; resistance level; second harmonic mode;
fLanguage
English