• DocumentCode
    778360
  • Title

    Rejection of Nal Pulse Pile-Up in Linac Bremsstrahlung Measurements

  • Author

    McGuire, R.L. ; Sandifer, C.W.

  • Author_Institution
    Edgerton, Germeshausen & Grier, Inc. Santa Barbara, California
  • Volume
    13
  • Issue
    1
  • fYear
    1966
  • Firstpage
    315
  • Lastpage
    320
  • Abstract
    A pulse pile-up rejection system was developed and used successfully with a NaI gamma spectrometer to measure the bremsstrahlung spectral distribution from a 0.2-radiation-length gold-tungsten target bombarded by high energy electrons from a pulsed electron linear accelerator. The system utilizes a double differentiation technique to reject those scintillation events where more than one gamma ray is detected during a single linac pulse. The pulse pile-up rejection circuit was used effectively over a gamma energy range of 0.25 Mev to 21 Mev and increased data collection speed by about a factor of 20. The performance of the system agrees with theoretical predictions calculated on the basis of Poission statistics. Gamma spectral distributions measured with the system at the EG&G linac are presented to demonstrate utilization of the system.
  • Keywords
    Electrons; Energy measurement; Event detection; Gamma ray detection; Gamma ray detectors; Linear accelerators; Linear particle accelerator; Pulse measurements; Solid scintillation detectors; Spectroscopy;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1966.4323982
  • Filename
    4323982