• DocumentCode
    779763
  • Title

    Monte-Carlo Calculation of Intrinsic Double-Escape Peak Efficiency of Cylindrical Lithium-Drift Germanium Gamma Ray Detectors

  • Author

    de Castro Faria, N.V. ; Lévesque, R. J A

  • Author_Institution
    Département de Physique, Université de Montréal, Montréal, Canada
  • Volume
    13
  • Issue
    3
  • fYear
    1966
  • fDate
    6/1/1966 12:00:00 AM
  • Firstpage
    363
  • Lastpage
    366
  • Abstract
    Calculations of the intrinsic double-escape peak efficiency of cylindrical Li-Ge detectors for parallel beam of gamma rays ranging in energy from 1.5 to 10 MeV, were carried out using a computer code based on the Monte-Carlo method. The detectors considered are 18 mm. in diameter with 2, 3.5, 4, 5, 8 and 10 mm. depletion depth. Comparison is made with the experimental results of Ewan and Tavendale1 for a 18 × 3.5 mm. detector.
  • Keywords
    Electromagnetic scattering; Electromagnetic wave absorption; Gamma ray detection; Gamma ray detectors; Gamma rays; Germanium; History; Positrons; Probability distribution; Production;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1966.4324119
  • Filename
    4324119