DocumentCode
782578
Title
Low-Energy Electron and Proton Satellite Instrumentation for Auroral Studies
Author
Reagan, J.B. ; Carr, D.L. ; McDaniel, J.D. ; Sanders, T.C.
Author_Institution
Lockheed Palo Alto Research Laboratory Lockheed Missiles & Space Company Palo Alto, California
Volume
14
Issue
1
fYear
1967
Firstpage
49
Lastpage
55
Abstract
Several instruments employing variable-energy electrostatic thresholds and post-acceleration techniques in conjunction with plastic scintillator-photomultiplier detectors have been successfully used in a satellite experiment to measure low-energy electrons and protons in the auroral regions. A description of these instruments, which were designed to measure electrons in the energy range of 0.015 to 10.0 keV with detection sensitivities as high as 4 x 10-4 erg/cm2-sec-sr and protons in the energy range of 0.20 to 10.0 keV with detection sensitivities of 6 x 10-3erg/cm2-sec-sr, is given. A discussion of the procedures employed in the laboratory calibration of these instruments is presented. In-flight calibration techniques involving both radioactive sources and programmable Ga-P light diodes are also described. The performance of the instruments during two satellite flights in November, 1963, and November, 1965, is illustrated by the presentation of some typical data.
Keywords
Calibration; Detectors; Electrons; Electrostatic measurements; Energy measurement; Instruments; Laboratories; Plastics; Protons; Satellite broadcasting;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1967.4324394
Filename
4324394
Link To Document