DocumentCode
787369
Title
Satellite Instrumentation for Charged Particle Measurements IV. Solid State Spectrometers for 0.1 to 1.0 and 0.8 to 6.0 MeV Protons
Author
Paolini, F.R. ; Theodoridis, G.C. ; Welsh, W.F.
Author_Institution
American Science and Engineering Cambridge, Massachusetts
Volume
15
Issue
1
fYear
1968
Firstpage
205
Lastpage
209
Abstract
Solid-state proton spectrometers for OV1-13 are described. Pulses from totally-depleted transmission detectors are accepted for differential analysis only if unaccompanied by pulses in a back-up detector. Geometrical factors are 0.5 Ã 10-2 cm2 ster and 1.0 Ã 10-2 cm2-ster respectively for the lower and higher range instruments; energy bin-widths are approximately 20%. Similar instruments are giving good data from OV1-9.
Keywords
Detectors; Event detection; Instruments; Magnetic analysis; Particle measurements; Protons; Pulse amplifiers; Satellites; Solid state circuits; Spectroscopy;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1968.4324855
Filename
4324855