DocumentCode
788988
Title
The limit of fluxgate sensitivity due to Barkhausen noise for single layer and bi-layer permalloy thin film cores
Author
Farrell, G.P. ; Hill, E.W.
Author_Institution
Sch. of Eng., Manchester Univ., UK
Volume
31
Issue
6
fYear
1995
fDate
11/1/1995 12:00:00 AM
Firstpage
4050
Lastpage
4052
Abstract
In its simplest form, the thin film fluxgate sensor measures the applied magnetic field by determining the difference in switching field as the cores change their direction of magnetisation. The ultimate sensitivity of such a configuration is determined by the intrinsic variation, or jitter, in the switching field value from cycle to cycle due to Barkhausen noise in the cores. Comparisons of the noise performance of different cores may be made by examining the associated jitter noise power spectra. The results show that under ambient conditions a single layer permalloy film of thickness 100 nm is less noisy than a bi-layer film of the same magnetic thickness. If a hard axis bias field, Hb, is applied, however, then as the bias field approaches the anisotropy field, Hk, the performance of the single layer material worsens and that of the bi-layer improves. For Hb>0.5 Hk, the bi-layer film shows the better performance. There is an associated decrease in the height of the switching pulse as the magnetisation vector rotates through a smaller angle when the bias field is applied, but provided the detection electronics are able to resolve the pulse above the electronic noise floor, a suitably designed fluxgate sensor will continue to operate
Keywords
Barkhausen effect; Permalloy; ferromagnetic materials; jitter; magnetic anisotropy; magnetic cores; magnetic flux; magnetic noise; magnetic switching; magnetic thin films; magnetisation; sensitivity; Barkhausen noise; FeNi; anisotropy field; applied magnetic field; bilayer permalloy thin film cores; fluxgate sensitivity; jitter; magnetisation direction changes; magnetisation vector; single layer permalloy thin film cores; switching field; switching field value; switching pulse; thin film fluxgate sensor; Jitter; Magnetic anisotropy; Magnetic cores; Magnetic field measurement; Magnetic films; Magnetic noise; Magnetic sensors; Magnetic switching; Magnetization; Thin film sensors;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.489858
Filename
489858
Link To Document