DocumentCode
789865
Title
Calibration of the Self-Powered Neutron Flux Monitor in a Simulated PWR Lattice
Author
Baldwin, M.N. ; Rogers, J.E.
Author_Institution
The Babcock & Wilcox Company Lynchburg, Virginia
Volume
16
Issue
1
fYear
1969
Firstpage
171
Lastpage
176
Abstract
The response of a rhodium all-solid, self-powered incore monitor was measured in a critical assembly mock-up of a typical PWR. The detector signal strength and the power density of adjacent fuel rods were correlated. The detector background, typically 2 to 5%, was highly dependent on the detector environment as well as the incident gamma flux.
Keywords
Assembly; Boron; Calibration; Detectors; Inductors; Lattices; Monitoring; Neutrons; Signal detection; Wires;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1969.4325102
Filename
4325102
Link To Document