• DocumentCode
    789865
  • Title

    Calibration of the Self-Powered Neutron Flux Monitor in a Simulated PWR Lattice

  • Author

    Baldwin, M.N. ; Rogers, J.E.

  • Author_Institution
    The Babcock & Wilcox Company Lynchburg, Virginia
  • Volume
    16
  • Issue
    1
  • fYear
    1969
  • Firstpage
    171
  • Lastpage
    176
  • Abstract
    The response of a rhodium all-solid, self-powered incore monitor was measured in a critical assembly mock-up of a typical PWR. The detector signal strength and the power density of adjacent fuel rods were correlated. The detector background, typically 2 to 5%, was highly dependent on the detector environment as well as the incident gamma flux.
  • Keywords
    Assembly; Boron; Calibration; Detectors; Inductors; Lattices; Monitoring; Neutrons; Signal detection; Wires;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1969.4325102
  • Filename
    4325102