DocumentCode
790587
Title
Design and Performance of the Sandia Laboratories Hermes II Flash X-Ray Generator
Author
Martin, T.H.
Author_Institution
Sandia Laboratories Albuquerque, New Mexico
Volume
16
Issue
3
fYear
1969
fDate
6/1/1969 12:00:00 AM
Firstpage
59
Lastpage
63
Abstract
Pulsed power technology has grown rapidly during the last decade. Particular credit is due to research efforts at United Kingdom Atomic Weapons Research Establishment (AWRE). The largest machine presently in operation is the Sandia Laboratories Hermes II which has produced a 170 kA beam of electrons at energies of 12 million volts for times of 100 ns. This paper reviews the design and performance of the Hermes II and includes data from Hermes I, a prototype.