DocumentCode
792716
Title
A Differential Current Metering System for Location and Measurement of Leakage Currents in High Current DC Electrolytic Cell Line Circuits
Author
Yauch, Donald W.
Author_Institution
Halmar Electronics, Inc., Columbus, Ohio 43223.
Issue
4
fYear
1975
fDate
7/1/1975 12:00:00 AM
Firstpage
457
Lastpage
464
Abstract
The use of a portable differential current measurement system in the measurement of small leakage currents in high direct current electrochemical cell lines is discussed. Practical aspects are examined in the use of the equipment within copper refineries, chlorine cell lines, and aluminum smelters.
Keywords
Chemical industry; Circuits; Current measurement; Electric variables measurement; Environmental economics; Leakage current; Magnetic field measurement; Petroleum; Production; Size measurement;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.1975.349319