  • Abstract
    The usual uncoupled d - q model of salient pole synchronous machines (Park´s model) may be insufficient for accurate modeling of buried magnet permanent magnet machines. The addition of a nonbilateral coupling between the direct and quadrature axis equivalent circuits is shown to improve the steady-state model greatly. The cross coupling reactance has important implications in improving operation in the constant horsepower mode. In particular, it is demonstrated that the cross coupling term acts to reduce the effective internal voltage so that some field weakening can be achieved. The results should be useful in permanent magnet machine design for variable speed drive applications.
  • Keywords
    AC motors; Coupling circuits; Equivalent circuits; Permanent magnet machines; Permanent magnet motors; Reactive power; Servomotors; Synchronous machines; Synchronous motors; Voltage;