    Eddy-Current Probe-Type Sodium Flowsensor for FFTF Reactor Fuel Channel Flow Monitoring

  • Author

    Brewer, John ; Jaross, Robert A. ; Brown, Russell L.

  • Author_Institution
    Argonne National Laboratory Argonne, Illinois
  • Volume
    18
  • Issue
    1
  • fYear
    1971
  • Firstpage
    372
  • Lastpage
    377
  • Abstract
    An eddy-current probe-type flowsensor is being developed for the FFTF to indicate sodium flow velocity at the outlet of a fuel channel in a temperature range of 300??F to 1200??F and a velocity range of 0-18 fps. Design considerations, out-of-reactor tests, both dry and in sodium, were performed and results are presented. Typical sensitivity of 0.6 mV rms/ft-sec has been obtained with excellent stability.